Process optimization of waste activated sludge in anaerobic digestion and biogas production by electrochemical pre-treatment using ruthenium oxide coated titanium electrodes

Heng, G.C. and Isa, M.H. and Lock, S.S.M. and Ng, C.A. (2021) Process optimization of waste activated sludge in anaerobic digestion and biogas production by electrochemical pre-treatment using ruthenium oxide coated titanium electrodes. Sustainability (Switzerland), 13 (9). ISSN 20711050

Full text not available from this repository.
Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

Anaerobic digestion (AD) appears to be a popular unit operation in wastewater treatment plant to treat waste activated sludge (WAS) and the produced methane gas can be harvested as renewable energy. However, WAS could inhibit hydrolysis stage during AD and hence pre-treatment is required to overcome the issue. This paper aimed to study the effect of electrochemical pretreatment (EP) towards efficiency of AD using titanium coated with ruthenium oxide (Ti/RuO2) electrodes. The investigation has been carried out using in-house laboratory batch-scale mesophilic anaerobic digester, mixed under manipulation of important operating parameters. Optimization was performed on EP using response surface methodology and central composite design to maximize sludge disintegration and dewaterability. By operating at optimal conditions (pH 11.65, total solids 22,000 mg/L, electrolysis time 35 min, current density 6 mA/cm2, and 1000 mg/L of sodium chloride), the pre-treated WAS in terms of mixed liquor volatile suspended solids (MLVSS) removal, soluble chemical oxygen demand (sCOD), capillary suction time (CST) reduction, and extracellular polymeric substance (EPS) were 38, 4800 mg/L (increased from 935 mg/L), 33, and 218 mg/L, respectively. Following AD, the volatile solids (VS) removal and chemical oxygen demand (COD) removal by EP were enhanced from 40.7 and 54.7 to 47.2 and 61.5, respectively, at steady-state. The biogas produced from control and electrochemical pre-treated WAS were in the ranges of 0.12 to 0.17 and 0.2 to 0.24 m3/kg VSfed, respectively, and the volume of biogas produced was 44�67 over the control. Based on the results obtained, suitability of EP for WAS prior to AD was confirmed. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.

Item Type: Article
Additional Information: cited By 10
Uncontrolled Keywords: activated sludge; anaerobic digestion; biogas; electrochemical method; electrode; hydrolysis; optimization; oxide; waste technology; wastewater treatment plant
Depositing User: Mr Ahmad Suhairi UTP
Date Deposited: 10 Nov 2023 03:29
Last Modified: 10 Nov 2023 03:29
URI: https://khub.utp.edu.my/scholars/id/eprint/14966

Actions (login required)

View Item
View Item