TY - CONF VL - 2035 AV - none PB - American Institute of Physics Inc. ID - scholars9691 A1 - Jessam, R.A. A1 - Al-Kayiem, H.H. A1 - Nasif, M.S. UR - https://www.scopus.com/inward/record.uri?eid=2-s2.0-85057341099&doi=10.1063%2f1.5075598&partnerID=40&md5=642d9f265b3746a2fcdc9d9004310c27 N1 - cited By 2; Conference of 6th International Conference on Production, Energy and Reliability, ICPER 2018 ; Conference Date: 13 August 2018 Through 14 August 2018; Conference Code:141991 TI - Experimental and numerical analysis of different flow modifier on the reversal flow region in s-shaped aggressive diffuser Y1 - 2018/// SN - 0094243X N2 - This paper presents an experimental and numerical investigation on the flow modification in an air intake S-shaped aggressive diffuser. The selected diffuser has an actual geometry of 45°subsection from annular cross section, with implementing flow modifiers. The S-shaped diffuser had an area ratio 3.1 and turning angle of 35°/35°. The investigation is performed with three types of passive flow control flow modifiers. 3D CFD simulation was performed through ANSYS-FLUENT 15 software. The experimental results showed a good agreement with the numerical results. The measurements were conducted inside annular subsection at inlet Reynold number 40 � 104 and turbulence intensity 4.8. The performance parameters, static pressure recovery and distortion coefficient, used for performance evaluation. Implementing flow modifiers type 2 gives maximum static pressure recovery of 0.77, 0.83 and minimum distortion coefficient of 0.086, 0.077 for experimental and numerical results, respectively. While the less improvement was produced with implementing flow modifiers type 3. © 2018 Author(s). ER -