TY - JOUR ID - scholars9259 N2 - This paper presents a minimization of eddy-current loss (ECL) in permanent-magnet (PM) of three tubular linear PM motors (TLPMMs). Three-dimensional Finite-Element Analysis has been used for the simulations. The ECL component is usually not taken into consideration in conventional PM motors. In present technologies, ECL is generated inside magnets of PM motors, due to both the high conductivity of the rare-earth magnets and the harmonics of the slot. This loss can increase the temperature inside the magnets, and that may deteriorate their magnetic properties and potential risk of thermal demagnetization. Therefore, in the translator, segmented magnets has been used, because the cancellation of the ECL with this technique is possible as illustrated by the FEA results. Meanwhile, for the stator core of the three proposed motors, soft magnetic composite (SMC) material, Somaloy 700 has been used for its low cost and approximately zero ECL. IS - 3 VL - 7 A1 - Abdalla, I.I. A1 - Ibrahim, T. A1 - Perumal, N. A1 - Nor, N.M. JF - International Journal on Advanced Science, Engineering and Information Technology UR - https://www.scopus.com/inward/record.uri?eid=2-s2.0-85021048906&doi=10.18517%2fijaseit.7.3.2280&partnerID=40&md5=10830e707d4e31a74d4e39dea361718c Y1 - 2017/// TI - Minimization of eddy-current loss in a permanent-magnet tubular linear motor SP - 964 N1 - cited By 3 AV - none EP - 970 PB - Insight Society SN - 20885334 ER -