eprintid: 9106 rev_number: 2 eprint_status: archive userid: 1 dir: disk0/00/00/91/06 datestamp: 2023-11-09 16:21:03 lastmod: 2023-11-09 16:21:03 status_changed: 2023-11-09 16:14:17 type: conference_item metadata_visibility: show creators_name: Ahmed Kabir, I.F.S. creators_name: Kanagalingam, S. creators_name: Safiyullah, F. title: Performance evaluation of air flow and thermal comfort in the room with Wind-Catcher using different CFD techniques under neutral Atmospheric Boundary Layer ispublished: pub keywords: Air; Air conditioning; Atmospheric movements; Boundary layers; Computational fluid dynamics; Energy utilization; Ozone layer; Thermal comfort; Turbulence models; Ventilation, ASHRAE standards; CFD technique; K-E turbulence model; Natural ventilation; Ozone layer depletion; Thermal comfort analysis; Ventilation airs; Wind catchers, Atmospheric boundary layer note: cited By 12; Conference of 1st Joint Conference on World Engineers Summit - Applied Energy Symposium and Forum: Low Carbon Cities and Urban Energy, WES-CUE 2017 ; Conference Date: 19 July 2017 Through 21 July 2017; Conference Code:133340 abstract: Energy usage in buildings using conventional Heat Ventilation Air Conditioning (HVAC) systems can be considerably reduced on using natural ventilation systems like wind catcher. In addition to high energy consumptions in conventional HVAC, other disadvantages include ozone layer depletion due to CFCs emitted and also cost involved in installation and maintenance. Purpose of this study was to investigate the airflow and thermal comfort analyses of existing common wind catcher design in the city of Yazd using computational fluid dynamics (CFD) technique. In order to have more realistic analysis, neutral homogenous atmospheric boundary layer (ABL) was created at the inlet. Standard k-e turbulence model was used since equations for creating ABL were more related to this model. 3D CFD analysis was performed using both ANSYS FLUENT and OPENFOAM. Thermal comfort analysis was evaluated based on ASHRAE standard 55. © 2017 The Authors. Published by Elsevier Ltd. date: 2017 publisher: Elsevier Ltd official_url: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85040830298&doi=10.1016%2fj.egypro.2017.12.671&partnerID=40&md5=8052098f85e1038d59103973da288f03 id_number: 10.1016/j.egypro.2017.12.671 full_text_status: none publication: Energy Procedia volume: 143 pagerange: 199-203 refereed: TRUE issn: 18766102 citation: Ahmed Kabir, I.F.S. and Kanagalingam, S. and Safiyullah, F. (2017) Performance evaluation of air flow and thermal comfort in the room with Wind-Catcher using different CFD techniques under neutral Atmospheric Boundary Layer. In: UNSPECIFIED.