eprintid: 874
rev_number: 2
eprint_status: archive
userid: 1
dir: disk0/00/00/08/74
datestamp: 2023-11-09 15:49:01
lastmod: 2023-11-09 15:49:01
status_changed: 2023-11-09 15:38:38
type: conference_item
metadata_visibility: show
creators_name: Munir, H.A.
creators_name: Saad, N.
creators_name: Junid, S.A.A.S.
creators_name: Zaidi, A.M.A.
creators_name: Yusoff, M.Z.
creators_name: Jaffar, A.
title: Real-time communication between personal computer and programmable logic controller for networked control system based on Industrial Ethernet
ispublished: pub
keywords: Automation systems; Data rates; Fast ethernet; Industrial Ethernets; Networked Control System (NCS); Networked control systems; Programmable logic; Real-time; Real-time communication; Star topology, Communication systems; Computer control systems; Control theory; Controllers; Electric network topology; Ethernet; Industrial electronics; Industry; Personal communication systems; Personal computers; Programmed control systems, Computer control
note: cited By 1; Conference of 2010 International Conference on Computer Applications and Industrial Electronics, ICCAIE 2010 ; Conference Date: 5 December 2010 Through 7 December 2010; Conference Code:84532
abstract: Networked Control System (NCS) based communication system Industrial Ethernet (IE) becoming very popular for automation system. The Fast Ethernet system with data rate transfer 100Mb/s is used for this project. Star topology with the hub connected to Personal Computer (PC) and the others two Programmable Logic Controller (PLC) are analysis for the real-time communications. Real-time communication for the system are very good without no disconnected between PC and PLC. Data rate transfer is Okbit/s when the communications between PC and the others two PLC are idle. When the realtime communication is on between PC and PLC A with PCL B are idle, the data rate transfer shows 57 kbit/s. Meanwhile when the PC connected to the PLC B with PLC A are idle, the data rate transfer shown from the PC are 65 kbit/s. The other situations can be taken are when the PC connected to the PLC A and PLC B, the data rate transfer for the real time communication show 115 kbit/s. The highest data rate transfer shows from this project with 115 kbit/s are below the maximum data rate transfer IMbit/s for the PC with Fast Ethernet system. © 2010 IEEE.
date: 2010
official_url: https://www.scopus.com/inward/record.uri?eid=2-s2.0-79953875418&doi=10.1109%2fICCAIE.2010.5735007&partnerID=40&md5=3356b71342dc27678858f0c32a7b0ca0
id_number: 10.1109/ICCAIE.2010.5735007
full_text_status: none
publication: ICCAIE 2010 - 2010 International Conference on Computer Applications and Industrial Electronics
place_of_pub: Kuala Lumpur
pagerange: 610-614
refereed: TRUE
isbn: 9781424490554
citation:   Munir, H.A. and Saad, N. and Junid, S.A.A.S. and Zaidi, A.M.A. and Yusoff, M.Z. and Jaffar, A.  (2010) Real-time communication between personal computer and programmable logic controller for networked control system based on Industrial Ethernet.  In: UNSPECIFIED.