eprintid: 6841 rev_number: 2 eprint_status: archive userid: 1 dir: disk0/00/00/68/41 datestamp: 2023-11-09 16:18:38 lastmod: 2023-11-09 16:18:38 status_changed: 2023-11-09 16:07:48 type: conference_item metadata_visibility: show creators_name: Hamed, Y. creators_name: Shafie, A. creators_name: Mustaffa, Z.B. creators_name: Idris, N.R.B. title: An application of K-Nearest Neighbor interpolation on calibrating corrosion measurements collected by two non-destructive techniques ispublished: pub keywords: Corrosion; Gas pipelines; Interpolation; Magnetic leakage; Motion compensation; Nearest neighbor search; Nondestructive examination; Pipelines; Ultrasonic applications, Corrosion measurements; Inspection tools; Integrity assessment; K-nearest neighbors; Magnetic flux leakage; Measuring equipments; Non-destructive technique; Oil-and-Gas pipelines, Ultrasonic testing note: cited By 5; Conference of 3rd IEEE International Conference on Smart Instrumentation, Measurement and Applications, ICSIMA 2015 ; Conference Date: 24 November 2015 Through 25 November 2015; Conference Code:123651 abstract: Every measuring equipment or inspection tool is known to have its own accuracy, which may affect the reliability of its measurements. This affects Oil and Gas pipeline corrosion measurements, which may affect data reliability if not well interpreted. The inspection tolerance occurred in the measurements should be treated carefully for each equipment to prevented misinterpretation of the data which could lead to incorrect assessment. This paper presents a new application of K-Nearest Neighbor interpolation to calibrate corrosion measurements collected by Magnetic Flux Leakage intelligent pig (MFL-IP) with the readings of Ultrasonic Testing (UT) scan device. The final enhanced metrics will be used in the integrity assessment report of the pipeline to decide whether the pipeline is fit for service or needs certain maintenance. © 2015 IEEE. date: 2016 publisher: Institute of Electrical and Electronics Engineers Inc. official_url: https://www.scopus.com/inward/record.uri?eid=2-s2.0-84991047697&doi=10.1109%2fICSIMA.2015.7559030&partnerID=40&md5=21e9814617cf1b5eabb7224611405027 id_number: 10.1109/ICSIMA.2015.7559030 full_text_status: none publication: 2015 IEEE International Conference on Smart Instrumentation, Measurement and Applications, ICSIMA 2015 refereed: TRUE isbn: 9781467372558 citation: Hamed, Y. and Shafie, A. and Mustaffa, Z.B. and Idris, N.R.B. (2016) An application of K-Nearest Neighbor interpolation on calibrating corrosion measurements collected by two non-destructive techniques. In: UNSPECIFIED.