eprintid: 6155 rev_number: 2 eprint_status: archive userid: 1 dir: disk0/00/00/61/55 datestamp: 2023-11-09 16:17:54 lastmod: 2023-11-09 16:17:54 status_changed: 2023-11-09 16:05:03 type: article metadata_visibility: show creators_name: Gitan, A.A. creators_name: Abdulmalek, S.H. creators_name: Dihrab, S.S. title: Tracking collector consideration of tilted collector solar updraft tower power plant under Malaysia climate conditions ispublished: pub keywords: Heat transfer; Productivity; Solar energy; Surface discharges, Azimuth angles; Climate condition; Performance; Performance characteristics; Slope angles; Solar updraft towers; Tilted collector; Transfer relations, Collector efficiency, azimuth; climate conditions; efficiency measurement; energy efficiency; fixed structure; heat transfer; instrumentation; model validation; optimization; performance assessment; power generation; power plant; slope angle; solar power; tracking, Malaysia note: cited By 13 abstract: SUPP (Solar Updraft Tower power plant) is a technology in the power generation sector. The power productivity and efficiency represent important performance characteristics of SUPP. In the present work a mathematical model was developed to estimate the performance of SUPP based on tracking solar collector consideration in Malaysia. The objective is to verify the suggested model and to optimize the slope angle of tilted tracking solar collector. Basically, the hourly solar data were analysed considering solar azimuth angle for tracking case calculation to determine the solar energy incident on the collector. Then, the useful energy gain was calculated based on heat transfer relations. The model was validated with experimental work and well agreement was achieved. Results revealed that the SUPP of slope collector angle of 10° can produce higher power generation over the whole the year. Also, the tracking solar consideration enhanced the performance characteristics especially the power productivity by around 3.5 kW over that of fixed collector. The maximum collector and SUPP efficiencies of 51 and 0.165 respectively were obtained. © 2015 Elsevier Ltd. date: 2015 publisher: Elsevier Ltd official_url: https://www.scopus.com/inward/record.uri?eid=2-s2.0-84954526769&doi=10.1016%2fj.energy.2015.09.009&partnerID=40&md5=bf13d2352b526d4dcff601f8184ee70d id_number: 10.1016/j.energy.2015.09.009 full_text_status: none publication: Energy volume: 93 pagerange: 1467-1477 refereed: TRUE issn: 03605442 citation: Gitan, A.A. and Abdulmalek, S.H. and Dihrab, S.S. (2015) Tracking collector consideration of tilted collector solar updraft tower power plant under Malaysia climate conditions. Energy, 93. pp. 1467-1477. ISSN 03605442