TY - CONF UR - https://www.scopus.com/inward/record.uri?eid=2-s2.0-85085405503&doi=10.2118%2f176307-ms&partnerID=40&md5=6f91a1bb6e06cc2e54659b7c17f95d97 A1 - Biyanto, T.R. A1 - Natawiria, A.D.S. A1 - Kusuma, F. A1 - Musyafa, A. A1 - Noriyati, R.D. A1 - Costa, S.D. A1 - Irawan, S. Y1 - 2015/// SN - 9781613993903 PB - Society of Petroleum Engineers N1 - cited By 0; Conference of SPE/IATMI Asia Pacific Oil and Gas Conference and Exhibition, APOGCE 2015 ; Conference Date: 20 October 2015 Through 22 October 2015; Conference Code:118474 N2 - Test interval is an action to verify Safety Integrity Function (SIF) availability. The detection of SIF availability is depends on appropriate test interval value. The test interval value could affect the value of Safety Integrity Level (SIL). This research proposed to demonstrate the effect of the test interval to the obtained value for the specified SIL on SIF. Therefore, SIL value will fit into the architecture of SIF. The case study that used in this paper is three phases separator. The save guards installed in this case are pressure SIF and the relief valve. The result of this research proved that the increasing value of test interval could increase the SIL value. The three phases separator case study with specific hazardous event frequency shown that 0.2 years or 2.4 months is the appropriate value for the test interval. Copyright 2015, Society of Petroleum Engineers. KW - Pressure relief valves; Separators KW - Hazardous events; Interval value; Safety instrumented function; Safety integrity functions; Safety integrity levels; Three phase; Three phasis KW - Safety engineering ID - scholars6071 TI - The effects of test interval on safety instrumented function (SIF) according to Safety Integrity Level (SIL) value on three phase separator application AV - none ER -