eprintid: 5928 rev_number: 2 eprint_status: archive userid: 1 dir: disk0/00/00/59/28 datestamp: 2023-11-09 16:17:40 lastmod: 2023-11-09 16:17:40 status_changed: 2023-11-09 16:04:16 type: article metadata_visibility: show creators_name: Okitsu, J. creators_name: Khamis, M.F.I. creators_name: Zakaria, N. creators_name: Naono, K. creators_name: Haruna, A.A. title: Toward an architecture for integrated gas district cooling with data center control to reduce CO2 emission ispublished: pub keywords: Carbon dioxide; Cooling; Cooling systems; Cooling water; District heating; Scheduling, Chilled water; Controllable parameters; Data centers; District cooling; Job scheduling; Outdoor temperature; Steam absorption; Temperature differences, Water supply note: cited By 8 abstract: Gas District Cooling (GDC) provides electricity and chilled water to facilities with relatively low running cost and has the potential to reduce CO2 emission as it can make effective use of wasted energy. However, the present CO2 emission tends to be higher than expected due to the chilled water supply-demand gap. To efficiently manage the gap, this paper introduces a novel chilled water supply-demand gap model and proposes an integrated GDC and Data Center (DC) control based on the model. The gap model, defined by GDC plant and DC controllable parameters, estimates the required additional chilled water supply. Then, DC and chillers in the plant are controlled based on the model to minimize the required additional supply. The analysis using GDC operational data in Universiti Teknologi PETRONAS shows that the accuracy of the models depends on temperature differences between rooms and outdoor, and Steam Absorption Chillers (SAC) operations. Thus, the analysis suggests that the incorporation of room and outdoor temperature sensors in the DC, and the proper scheduling of SAC operation can improve the accuracy of the models. The improved accuracy will in turn allows the GDC operation to be better optimized, resulting in a reduced CO2 emission. © 2014 Elsevier Inc. All rights reserved. date: 2015 publisher: Elsevier Inc. official_url: https://www.scopus.com/inward/record.uri?eid=2-s2.0-84937514664&doi=10.1016%2fj.suscom.2014.08.010&partnerID=40&md5=3531b02e1f23ce64b9fd63f94c92775e id_number: 10.1016/j.suscom.2014.08.010 full_text_status: none publication: Sustainable Computing: Informatics and Systems volume: 6 pagerange: 39-47 refereed: TRUE issn: 22105379 citation: Okitsu, J. and Khamis, M.F.I. and Zakaria, N. and Naono, K. and Haruna, A.A. (2015) Toward an architecture for integrated gas district cooling with data center control to reduce CO2 emission. Sustainable Computing: Informatics and Systems, 6. pp. 39-47. ISSN 22105379