TY - JOUR EP - 114 PB - International Journal of Renewable Energy Research SN - 13090127 SP - 109 TI - Standalone photovoltaic system sizing using peak sun hour method and evaluation by TRNSYS simulation N1 - cited By 18 AV - none VL - 4 JF - International Journal of Renewable Energy Research A1 - Al Riza, D.F. A1 - Gilani, S.I.-U.H. UR - https://www.scopus.com/inward/record.uri?eid=2-s2.0-84897082181&partnerID=40&md5=a46d2b93b0d9c13656e57a98e6a8fd03 Y1 - 2014/// ID - scholars5449 N2 - This paper presents sizing and evaluation of a standalone photovoltaic system for residential load. Peak Sun Hour method is used to determine photovoltaic panel and battery capacity, then the sizing results are tested and evaluated using hourly time-step transient simulation model by using TRNSYS 16.0. The results show for typical Malaysian terraced house that has about 6 kWh daily electricity load, the photovoltaic system requirement consists of 1.9 kWp photovoltaic panel and 2200 Ah battery capacity for a 24V system. IS - 1 ER -