relation: https://khub.utp.edu.my/scholars/5214/ title: Evaluation of multi storey structures in Malaysia creator: Potty, N.S. creator: Hamid, M.R.A. description: Malaysia has not traditionally considered earthquake and hurricane loading in design. Several tremors in neighboring countries necessitated a relook at the seismic reliability of structures in Kuala Lumpur and Penang with significant seismic risk. The study started with simple vertical load analysis (the current practice) and then the earthquake and the wind loading were imposed. The integrity of structures was evaluated for serviceability deflections using UBC 1997, IS 875-3-1987 and IS 1893. Permissible deflections were exceeded at 40 m/s for 87 m height buildings; at 45m/s for above 70 m height buildings; at 50 m/s for buildings above 59.5 m height. Higher value of ground accelerations (>0.1 g) results in exceeding the serviceability deflections © (2014) Trans Tech Publications, Switzerland. publisher: Trans Tech Publications Ltd date: 2014 type: Article type: PeerReviewed identifier: Potty, N.S. and Hamid, M.R.A. (2014) Evaluation of multi storey structures in Malaysia. Applied Mechanics and Materials, 567. pp. 571-576. ISSN 16609336 relation: https://www.scopus.com/inward/record.uri?eid=2-s2.0-84903543009&doi=10.4028%2fwww.scientific.net%2fAMM.567.571&partnerID=40&md5=f4130af3673e56cf71d3853776c6b9b0 relation: 10.4028/www.scientific.net/AMM.567.571 identifier: 10.4028/www.scientific.net/AMM.567.571