eprintid: 4287 rev_number: 2 eprint_status: archive userid: 1 dir: disk0/00/00/42/87 datestamp: 2023-11-09 16:15:57 lastmod: 2023-11-09 16:15:57 status_changed: 2023-11-09 15:58:06 type: conference_item metadata_visibility: show creators_name: Al-Kayiem, H.H. creators_name: Al-Habeeb, L.N. title: Ribbed double pipe heat exchanger: Experimental analysis ispublished: pub keywords: Flow of fluids; Friction; Heat convection; Mass transfer; Reynolds number; Turbulence, Annular flows; Artificial roughening; Double-pipe heat exchangers; Enhanced heat transfer; Experimental analysis; Performance enhancements; Pitch-to-height ratio; Turbulence promoters, Heat exchangers note: cited By 2; Conference of 13th International Conference on Simulation and Experiments in Heat and Mass Transfer, HT 2014 ; Conference Date: 2 July 2014 Through 4 July 2014; Conference Code:107063 abstract: Convection heat transfer can be enhanced by imposed turbulence in the annular flow of a double pipe heat exchanger. This paper presents and discusses the results obtained from experimental measurement by the installation of turbulence promoters, having rib configuration, on the inner surface of the cold flow annulus of a counter flow double-pipe heat exchanger. The promoters have been selected with rib�s height to hydraulic diameter, e/Dh equal to 0.107 and two pitch to height ratios, p/e equal to 10 and 15. The annular cold flow was investigated within Reynolds number range of 2000 to 20000. The measured data enabled us to estimate the friction factor, Reynolds number and Stanton number of each case in order to analyse the performance enhancement of the double pipe heat exchanger. The results showed that enhancement in the heat transfer, in terms of the Stanton number, was combined with a small penalty in the pressure drop, which was due to an increase in the friction factor values. Within the tested ranges of e/Dh and Re, the performance index indicated enhancement of about 1.3 to 1.8 at pitch to p/e = 10. It is recommended to investigate more cases of rib�s heights and installation in the hot fluid flow side. © 2014 WIT Press. date: 2014 publisher: WITPress official_url: https://www.scopus.com/inward/record.uri?eid=2-s2.0-84907663439&doi=10.2495%2fHT140011&partnerID=40&md5=fd18020053820834ece7f25e93493ac0 id_number: 10.2495/HT140011 full_text_status: none publication: WIT Transactions on Engineering Sciences volume: 83 pagerange: 3-14 refereed: TRUE isbn: 9781845647940 issn: 17433533 citation: Al-Kayiem, H.H. and Al-Habeeb, L.N. (2014) Ribbed double pipe heat exchanger: Experimental analysis. In: UNSPECIFIED.