title: Avoiding under-reaching in twin circuit lines without residual current input from the parallel line
ispublished: pub
keywords: Boolean functions; Computer networks; Electric breakdown; Electric current measurement; Electric fault location; Electric power system protection; Iterative methods; Parallel algorithms; Relay protection, Distance measurement; Fault location; Mutual coupling; Power system faults; Power system relaying; Power transmission; Protective relaying, Coupled circuits
note: cited By 0; Conference of 8th International Power Engineering Conference, IPEC 2007 ; Conference Date: 3 December 2007 Through 6 December 2007; Conference Code:73164
abstract: Mutual coupling presents difficult problems during single phase to earth fault, in transmission line protection. In lines, on multiple circuit towers or on the same right of way, the zero-sequence circuits of the lines get mutually coupled, causing an error in the apparent impedance seen by the relay. This causes the distance protection relay at one end of the faulty line to overreach and the relay at the other end to under-reach. Also, incorrect sensing of the ground fault due to zero-sequence voltage inversion caused by mutual coupling in the zero-sequence network may lead to false trip of the neighbouring healthy line. The paper develops characteristic expressions for the effective sequence impedances experienced by a twin-circuit, both with and without mutual coupling and presents a non-iterative microprocessor based real time algorithm for computing fault distance and zero sequence compensation in basic distance relaying scheme, Residual current measurement from the parallel circuit is not required in the algorithm. © 2007 RPS.
date: 2007
official_url: https://www.scopus.com/inward/record.uri?eid=2-s2.0-51349145178&partnerID=40&md5=57d228a11547e05d153b3406b08010b7
full_text_status: none
publication: 8th International Power Engineering Conference, IPEC 2007
place_of_pub: Singapore
pagerange: 1115-1120
refereed: TRUE
isbn: 9789810594237
citation:   Mukerjee, R.N. and Bin Abdullah, M.F. and Tan, K.K. and Nallagownden, P.  (2007) Avoiding under-reaching in twin circuit lines without residual current input from the parallel line.  In: UNSPECIFIED.