<mets:mets xsi:schemaLocation="http://www.loc.gov/METS/ http://www.loc.gov/standards/mets/mets.xsd http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd" LABEL="Eprints Item" OBJID="eprint_20461" xmlns:mods="http://www.loc.gov/mods/v3" xmlns:mets="http://www.loc.gov/METS/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xlink="http://www.w3.org/1999/xlink"><mets:metsHdr CREATEDATE="2026-04-08T21:19:09Z"><mets:agent ROLE="CUSTODIAN" TYPE="ORGANIZATION"><mets:name>UTP Scholars</mets:name></mets:agent></mets:metsHdr><mets:dmdSec ID="DMD_eprint_20461_mods"><mets:mdWrap MDTYPE="MODS"><mets:xmlData><mods:titleInfo><mods:title>Improvement of DGA interpretation using scoring index method</mods:title></mods:titleInfo><mods:name type="personal"><mods:namePart type="given">Norazhar Abu</mods:namePart><mods:namePart type="family">Bakar</mods:namePart><mods:role><mods:roleTerm type="text">author</mods:roleTerm></mods:role></mods:name><mods:name type="personal"><mods:namePart type="given">A.</mods:namePart><mods:namePart type="family">Abu-Siada</mods:namePart><mods:role><mods:roleTerm type="text">author</mods:roleTerm></mods:role></mods:name><mods:name type="personal"><mods:namePart type="given">Huize</mods:namePart><mods:namePart type="family">Cui</mods:namePart><mods:role><mods:roleTerm type="text">author</mods:roleTerm></mods:role></mods:name><mods:name type="personal"><mods:namePart type="given">Shengtao</mods:namePart><mods:namePart type="family">Li</mods:namePart><mods:role><mods:roleTerm type="text">author</mods:roleTerm></mods:role></mods:name><mods:abstract>Dissolved gas analysis (DGA) is the most effective method to detect incipient faults in power transformers. It uses the concentrations of various gases dissolved in the transformer oil due to decomposition of the oil and paper insulation. Gases such as hydrogen, methane, acetylene, ethylene, and ethane are generated as a results of oil decomposition, while carbon monoxide and carbon dioxide are generated due to the paper degradation. In the meantime, faults such as partial discharge, overheating, and arcing produce a range of gases. The concentrations of these gases can be used to identify faults and estimate their severity. Various techniques have been developed to interpret DGA results such the key gas method, Doernenburg, Rogers, IEC ratio-based methods, Duval triangles, and the latest Duval Pentagon methods. However, each of these techniques relies on the accumulated knowledge and experience of experts rather than quantitative scientific models, therefore different diagnoses may be reported for the same oil sample. Hence the accountability of the judgment is questionable if it only relies on one interpretation technique. This paper proposes the use of scoring point method to improve the accountability of DGA interpretation process. In this context, DGA results of several transformer oil samples are analyzed with four existing interpretation techniques; Doernenburg, Rogers, IEC, and Duval triangle methods from which a scoring index is developed for all fault types. Based on this analysis, each technique is assigned with specific weighting factor. The summation of scoring point times weightage represents the scoring index for particular faults. The proposed method is validated through DGA historical data of various transformers of pre-known health condition and life span. Results show that the proposed method can increase the accuracy of the DGA interpretation process. © 2017 IEEE.</mods:abstract><mods:originInfo><mods:dateIssued encoding="iso8601">2017</mods:dateIssued></mods:originInfo><mods:originInfo><mods:publisher>Institute of Electrical and Electronics Engineers Inc.</mods:publisher></mods:originInfo><mods:genre>Conference or Workshop Item</mods:genre></mets:xmlData></mets:mdWrap></mets:dmdSec><mets:amdSec ID="TMD_eprint_20461"><mets:rightsMD ID="rights_eprint_20461_mods"><mets:mdWrap MDTYPE="MODS"><mets:xmlData><mods:useAndReproduction>
<p xmlns="http://www.w3.org/1999/xhtml"><strong>For work being deposited by its own author:</strong>
In self-archiving this collection of files and associated bibliographic
metadata, I grant UTP Scholars the right to store
them and to make them permanently available publicly for free on-line.
I declare that this material is my own intellectual property and I
understand that UTP Scholars does not assume any
responsibility if there is any breach of copyright in distributing these
files or metadata. (All authors are urged to prominently assert their
copyright on the title page of their work.)</p>

<p xmlns="http://www.w3.org/1999/xhtml"><strong>For work being deposited by someone other than its
author:</strong> I hereby declare that the collection of files and
associated bibliographic metadata that I am archiving at
UTP Scholars is in the public domain. If this is
not the case, I accept full responsibility for any breach of copyright
that distributing these files or metadata may entail.</p>

<p xmlns="http://www.w3.org/1999/xhtml">Clicking on the <em>Deposit Item Now</em> button indicates your agreement to these
terms.</p>
    </mods:useAndReproduction></mets:xmlData></mets:mdWrap></mets:rightsMD></mets:amdSec><mets:fileSec></mets:fileSec><mets:structMap><mets:div DMDID="DMD_eprint_20461_mods" ADMID="TMD_eprint_20461"></mets:div></mets:structMap></mets:mets>