TY - CONF VL - 767 ID - scholars20446 N2 - Studies show that acids influence the electrical insulation strength of transformer insulating oil. Thus, this study was conducted to verify the influence of Low Molecular Acid (LMA) and High Molecular Acid (HMA) on the breakdown voltage of transformer insulating oil. Different weight of LMA and HMA were added into transformer insulating oil samples and then mixed using hotplate magnetic stirrer at 50C and 750 rpm for 3 hours. Prior to the mixing process, mineral insulating oil samples were filtered, dried and its moisture content were determined according to ASTM D1533 standard test condition. After the mixing process, total acid number (TAN) and AC breakdown voltage (BdV) of the oil mixtures were measured according to standard test conditions of ASTM D974 and ASTM D1816 respectively. The obtained results verified that LMA significantly reduced the breakdown voltage of mineral insulating oil compared to HMA for acidity lower than 1 mg KOH/g. © Published under licence by IOP Publishing Ltd. SN - 17578981 UR - https://www.scopus.com/inward/record.uri?eid=2-s2.0-85083117992&doi=10.1088%2f1757-899X%2f767%2f1%2f012063&partnerID=40&md5=adc97293c24928df9bc9c3094d2fda00 N1 - Cited by: 5; All Open Access, Gold Open Access AV - none TI - Effect of acids formation on the breakdown voltage properties of transformer insulating oil Y1 - 2020/// A1 - Chairul, Imran Sutan A1 - Ghani, Sharin Ab A1 - Bakar, Norazhar Abu A1 - Rahim, Nor Hidayah A1 - Ab Aziz, Nur Hakimah PB - Institute of Physics Publishing ER -