%D 2024 %R 10.1016/j.yofte.2024.103687 %O cited By 0 %J Optical Fiber Technology %L scholars19864 %K Aluminum; Diaphragms; Fiber Bragg gratings; Pipelines; Rubber, Leak localization; Localization performance; Low pressure pipeline; Low pressures; Negative pressure wave; Negative pressure wave methods; Negative pressure waves; Pipeline leak localization; Pressure pipeline; Rubber-based diaphragm fiber bragg grating pressure sensor, Pressure sensors %X Leak localization performance between rubber-based diaphragm fibre Bragg grating (FBG) pressure sensors and aluminium-based diaphragm FBG pressure sensors were compared and studied. A total of two aluminium-based and two rubber-based diaphragm FBG pressure sensors were fitted on a pipe with various leak points and sizes. Calibration test results showed that rubber-based diaphragm FBG pressure sensors are 30 times much higher as compared to aluminium-based diaphragm FBG pressure sensors at 93.2 pm/kPa and 96.6 pm/kPa. For leak localization test using negative pressure wave (NPW), rubber-based diaphragm FBG pressure sensors capable to localize accurately the leak location with percentage of error less than 10 . This is due to the high pressure resolution produced by the rubber-based diaphragm FBG pressure sensors. © 2024 Elsevier Inc. %T Low pressure pipeline leak localization using highly sensitive rubber-based diaphragm FBG pressure sensors and NPW method %A E. Vorathin %A M.X. Choong %A M. Mohammad %A A.R. Othman %A A.R. Ismail %V 83