TY - JOUR SP - 557 AV - none ID - scholars1918 CY - Chongqing EP - 561 N2 - All electrical motor or generator bearings can potential suffers from electric erosion. Unfortunately, problems can start after just a few months of running a new electric motor or generator. From visual inspection, it was found that the failure happened on the raceway surface in equal spacing. There may be many reasons for this - heavier loading than has been anticipated, inadequate or unsuitable lubrication, careless handling, ineffective sealing, or fits that are too tight, with resultant insufficient internal bearing clearance. Each of these factors produces its own particular type of damage and leaves its own special imprint on the bearing. Consequently, by examining a damaged bearing such as visual inspection, it is possible, in the majority of cases, to form an opinion on the cause of the damage and to take the requisite action to prevent a recurrence. © (2011) Trans Tech Publications. SN - 16609336 KW - Bearing clearance; Electric erosion; Electrical motors; Premature failures; Visual inspection KW - Electric locomotives; Electric motors; Inspection; Manufacture; Roller bearings KW - Electric generators TI - Visual inspection on premature failure of electric motor bearings VL - 84-85 JF - Applied Mechanics and Materials N1 - cited By 0; Conference of International Conference on Green Power, Materials and Manufacturing Technology and Applications, GPMMTA2011 ; Conference Date: 15 July 2011 Through 18 July 2011; Conference Code:86279 UR - https://www.scopus.com/inward/record.uri?eid=2-s2.0-80052177399&doi=10.4028%2fwww.scientific.net%2fAMM.84-85.557&partnerID=40&md5=143749315ed6400b71a81e40b7b1a6a8 A1 - Sutjipto, A.G.E. A1 - Triwiyanto, A. A1 - Aminanda, Y. A1 - Faris, W.F. A1 - Adesta, E.Y.T. Y1 - 2011/// ER -