eprintid: 16179 rev_number: 2 eprint_status: archive userid: 1 dir: disk0/00/01/61/79 datestamp: 2023-12-19 03:22:44 lastmod: 2023-12-19 03:22:44 status_changed: 2023-12-19 03:05:47 type: article metadata_visibility: show creators_name: Yap, Y.K. creators_name: Oh, P.C. creators_name: Chew, T.L. creators_name: Asif, J. title: Influence of alternating magnetic field's frequency and exposure time on distribution of α-Fe2O3/TiO2 fillers for gas separation membranes: Quantitative approach ispublished: pub keywords: Agglomeration; Dispersions; Filled polymers; Gas permeable membranes; Hematite, Alternating magnetic field; Dispersion analysis; Exposed to; Exposure-time; Field exposure; Filler magnetization; Gas separation membrane; Magnetic field frequency; Mixed-matrix membranes; Quantitative dispersion analyse, Fillers note: cited By 0 abstract: Poly(2,6-dimethyl-1,4-phenylene oxide) membrane with magnetic α-Fe2O3/TiO2 fillers was exposed to varying alternating magnetic field (AMF) duration and frequency. The AMF threshold time was 8 min as mixed-matrix membrane (MMM) exposed to 11 min experienced an abrupt increase in permeability of CO2 by 785 and CH4 by 1322. Although quantitative measurements showed relatively excellent values at 11 min, prolonged exposure time reduces selectivity, possibly due to interruption in the polymer-filler interfacial area densification process. Filler distribution measured quantitatively via optical microscope and MATLAB also revealed that MMM exposed to 3.3 kHz presents the greatest dispersion metric with the least agglomeration. MMM exposed to the frequency of 30 Hz or 330 kHz suffered from either increased agglomeration size or worse dispersion. Consequently, their gas separation performances were lower than MMM exposed to 3.3 kHz. Above a critical frequency, repulsive hydrodynamic forces overcome the attractive forces between magnetic fillers. © 2022 Wiley Periodicals LLC. date: 2022 publisher: John Wiley and Sons Inc official_url: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85137736830&doi=10.1002%2fapp.53093&partnerID=40&md5=4e93026eb9a9a088264a4401be35d191 id_number: 10.1002/app.53093 full_text_status: none publication: Journal of Applied Polymer Science volume: 139 number: 44 refereed: TRUE issn: 00218995 citation: Yap, Y.K. and Oh, P.C. and Chew, T.L. and Asif, J. (2022) Influence of alternating magnetic field's frequency and exposure time on distribution of α-Fe2O3/TiO2 fillers for gas separation membranes: Quantitative approach. Journal of Applied Polymer Science, 139 (44). ISSN 00218995