TY - JOUR IS - 4 ID - scholars12029 UR - https://www.scopus.com/inward/record.uri?eid=2-s2.0-85073391392&doi=10.14311%2fAP.2019.59.0399&partnerID=40&md5=bace166add73bc537ef5fbca9ca451df AV - none Y1 - 2019/// N1 - cited By 2 N2 - This article presents a design and commissioning of a multiphase flow loop, which was developed for scrutinizing the partial phase separation characteristics of pipe Tees. Its length is 9 m and its primary diameter is 0.078 m (3 inches). For the ease of modification, its design was kept modular, so that it could be used for testing various other pipe profiles. To validate this flow loop, the separation of a stratified-wavy flow was tested in a regular diameter ratio pipe Tee, and the gathered results were compared with previously published data. A good agreement was observed between the two data sources, which suggests that this flow loop is suitable for a further experimentation. © Czech Technical University in Prague, 2019. A1 - Saieed, A. A1 - Memon, Z.Q. A1 - Tran, M.C. A1 - Soon, W.P.K. SP - 399 EP - 410 SN - 18052363 TI - A multiphase flow loop design for investigating the partial phase separation in a pipe tee VL - 59 PB - Czech Technical University in Prague JF - Acta Polytechnica ER -