Al Riza, D.F. and Gilani, S.I.-U.H. (2014) Standalone photovoltaic system sizing using peak sun hour method and evaluation by TRNSYS simulation. International Journal of Renewable Energy Research, 4 (1). pp. 109-114. ISSN 13090127
Full text not available from this repository.Abstract
This paper presents sizing and evaluation of a standalone photovoltaic system for residential load. Peak Sun Hour method is used to determine photovoltaic panel and battery capacity, then the sizing results are tested and evaluated using hourly time-step transient simulation model by using TRNSYS 16.0. The results show for typical Malaysian terraced house that has about 6 kWh daily electricity load, the photovoltaic system requirement consists of 1.9 kWp photovoltaic panel and 2200 Ah battery capacity for a 24V system.
Item Type: | Article |
---|---|
Additional Information: | cited By 18 |
Depositing User: | Mr Ahmad Suhairi UTP |
Date Deposited: | 09 Nov 2023 16:17 |
Last Modified: | 09 Nov 2023 16:17 |
URI: | https://khub.utp.edu.my/scholars/id/eprint/5449 |