Ribbed double pipe heat exchanger: Analytical analysis

Al-Kayiem, H.H. and El-Rahman, M.F. (2011) Ribbed double pipe heat exchanger: Analytical analysis. Journal of Engineering Science and Technology, 6 (1). pp. 39-49. ISSN 18234690

Full text not available from this repository.
Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

This paper presents the findings obtained by modeling a Double Pipe Heat Exchanger (DPHE) equipped with repeated ribs from the inside for artificial roughing. An analytical procedure was developed to analyze the thermal and hydraulic performance of the DPHE with and without ribbing. The procedure was verified by comparing with experimental reported results and they are in good agreement. Several parameters were investigated in this study including the effect of ribs pitch to height ratios, P/e= 5, 10, 15, and 20, and ribs to hydraulic diameter ratios, e/Dh= 0.0595, 0.0765, and 0.107. These parameters were studied at various operating Reynolds number ranging from 2500 to 150000. Different installation configurations were investigated, too. An enhancement of 4 times in the heat transfer in terms of Stanton number was achieved at the expense of 38 times increase of pressure drop across the flow in terms of friction facto values. © School of Engineering, Taylor's University.

Item Type: Article
Additional Information: cited By 7
Depositing User: Mr Ahmad Suhairi UTP
Date Deposited: 09 Nov 2023 15:50
Last Modified: 09 Nov 2023 15:50
URI: https://khub.utp.edu.my/scholars/id/eprint/2251

Actions (login required)

View Item
View Item