Exergy based performance analysis of a gas turbine at part load conditions

Baheta, A.T. and Gilani, S.H. (2011) Exergy based performance analysis of a gas turbine at part load conditions. Journal of Applied Sciences, 11 (11). pp. 1994-1999. ISSN 18125654

Full text not available from this repository.
Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

A gas turbine can run at off-design due to change of ambient conditions or load demand. This needs to study how part load affect the gas turbine performance. The gas turbine considered for this study consists of variable stator vanes (VSVs). The VSVs are re-staggered for load greater than 50 so that it would increase exhaust gas temperature. For load less than 50 the VSVs are fully opened. The merit of the gas turbine system should be determined using exergy analyses because energy analyses tend to overestimate performance. Therefore, exergy model of each gas turbine component is formulated. A 4.2 MW gas turbine is analyzed for a wide range of part load condition. It is found that, at full load, the exergy destruction in the combustor is 48.9 and the loss with the exhaust gas is 35.8. The reminder is being destroyed in the turbine and compressor is 10.8 and 4.3, respectively. For comparison purpose both the first and second law efficiencies of each component are represented together. This analysis would help to identify the equipment where the potential for performance improvement is high, and trends, which may aid in the design of future plants. © Asian Network for Science Information.

Item Type: Article
Additional Information: cited By 6
Depositing User: Mr Ahmad Suhairi UTP
Date Deposited: 09 Nov 2023 15:50
Last Modified: 09 Nov 2023 15:50
URI: https://khub.utp.edu.my/scholars/id/eprint/2098

Actions (login required)

View Item
View Item