Flexible laser-induced graphene electrodes on polyimide film: Hybrid nanoflower-modified dielectric microjunctions for non-faradaic analysis

Subramani, I.G. and Remesh, S. and Perumal, V. and Gopinath, S.C.B. and Karuppanan, S. and Raja, P.B. and Ovinis, M. and Arumugam, N. and Kumar, R.S. (2024) Flexible laser-induced graphene electrodes on polyimide film: Hybrid nanoflower-modified dielectric microjunctions for non-faradaic analysis. Biochemical Engineering Journal, 208.

Full text not available from this repository.
Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

Laser-induced Graphene (LIG) electrodes on flexible substrates have attracted significant research interest, making them an excellent alternative to conventional fabrication of transducers on rigid planar substrates. In this study, four individual capacitor-like triangular LIG electrodes were fabricated on polyimide (PI) film with micron gap (MG) spacing of 30, 66, 125 and 180 µm, to study the relationship between gap spacing and capacitance. A novel N, N-carbonyldiimidazole-copper (CDI-Cu) hybrid nanoflower (NF) was synthesised via one-pot biomineralization and deposited at the triangular junction of acid-base treated LIG-MG for the immobilization of neutravidin. The gap spacing and structure of the LIG-MG were analysed using high-resolution microscopes, revealing a porous nanofiber-like graphene structure. X-ray Photoelectron Spectroscopy (XPS) of acid-base treated PI film proved carboxyl group formation. A decrease in capacitance was observed with an increasing gap spacing in a non-faradaic environment. The capacitance of CDI-Cu NF following neutravidin modification for 30, 66, 125 and 180 µm spacings were 1.77E-07, 1.36E-07, 4.73E-08, 4.84E-08 F, respectively, suggesting excellent biomolecular modification sensitivity of the LIG-MG with 30 µm spacing. A comparative analysis of dielectric performance for different gap-spaced devices revealed that a 30 µm spacing would be optimal for bio-capturing because of the close confinement of biomolecules for smaller gapped areas. © 2024 Elsevier B.V.

Item Type: Article
Additional Information: cited By 0
Uncontrolled Keywords: Biomineralization; Capacitance; Copper compounds; Graphite electrodes; Nanoflowers; Polyimides; X ray photoelectron spectroscopy, Biomodification; Carbon material; Dielectrode; Gap spacing; Graphene electrodes; Hybrid nanostructures; Laser induced; Micro gaps; Micro-gap spacing; Polyimide film, Graphene, carbon; carboxyl group; copper; graphene; nanofiber; nanoflower; nanomaterial; polyimide, Article; biomineralization; conductance; controlled study; dielectric constant; electric field; electric potential; elemental analysis; field emission scanning electron microscopy; hybrid; hydrolysis; impedance; incubation time; morphology; performance; synthesis; X ray photoemission spectroscopy
Depositing User: Mr Ahmad Suhairi UTP
Date Deposited: 04 Jun 2024 14:19
Last Modified: 04 Jun 2024 14:19
URI: https://khub.utp.edu.my/scholars/id/eprint/19573

Actions (login required)

View Item
View Item